Analysis Detail

ISOBank Number: 348243

Lab Sample ID
28
User Sample ID
28
Sample Measurement ID
ARDUOUS-14649

Measurements

Measurement Type Value Unit Scale
C:N Ratio n/a n/a
87Sr/86Sr 0.70805 None None

Additional Metadata

Collected Sample
Collected Sample Identifier
28
Quality Assurance and Control
Analysis Type
bulk water
Analytical Matrix or Compound
water
Instrumentation
TIMS
Primary Reference Material
SRM987
Quality Control Material Precision
0.0000200
Material Sample
Material Type
water solute
Preparation Step
other
Collection Context
Collected Sample Source
field
Related Publication
Related Publication Citation
Ladegaard-Pedersen P et al. Constraining a Bioavailable Strontium Isotope Baseline for the Lake Garda Region, Northern Italy: A Multi-Proxy Approach. Journal of Archaeological Science, Reports, vol. 41, 2022, p. 103339-
Related Publication Identifier
https://doi.org/10.1016/j.jasrep.2022.103339
Related Publication Identifier Type
DOI
Investigator Information
Investigator Email
robertf@ign.ku.dk
Investigator Name
Robert Frei
Collection Location
Collection Latitude (Decimal Degrees)
45.62
Collection Locality
Cornedo Vicentino
Collection Longitude (Decimal Degrees)
11.32
Material-specific Information
Water Source
river or stream